All new development must present an attractive, coordinated streetscape, incorporate architectural and site design elements appropriate to a pedestrian scale and provide for the safety and convenience of pedestrians. All new development shall comply with the following architectural standards:

A. Walls. No more than three materials shall be used for primary wall surfaces. Exterior finishes shall be of traditional, time- and weather-tested techniques. Retaining and screening walls shall be of materials complementary to the building’s materials. Buildings shall use a cohesive palette of colors which complement nearby buildings. Without limiting the use of color, large areas of wall shall be subdued in color and not reflective. Intense colors should be used as accent only.

B. Roofs. All the roofs and dormer roofs of a building shall be constructed of the same material. Slopes of roofs shall be of equal pitch if a gable or hip roof is employed. All metal roofs must be of a subdued color. Painted roof shingles are prohibited.

C. Fences, Hedges, and Walls. The following standards apply to new development of fences, hedges and walls:

1. Required Setbacks. A fence, hedge, wall, column, pier, post, or any similar structure or any combination of such structures is permitted in the required setback of a zone district if it meets the following conditions:

a. All fences and walls meet the requirements of Title 15, Buildings and Construction;

b. No fence, hedge, or wall extends beyond or across a property line without a recorded agreement with the abutting property owner;

c. Reserved;

d. Only one fence or wall shall be allowed per property line. Double fences, walls or combinations thereof are prohibited; and

e. No barbed wire or other sharp, pointed, or electrically charged fence may be erected or maintained, except a temporary fence on a construction site to protect the property during the period of construction may be topped with barbed wire where the barbed wire is not less than eight feet above the ground and does not extend more than two feet above the temporary fence.

2. Height. No fence structures may exceed seven feet in height, four feet in height from the front of the primary structure forward, or three feet in the sight distance triangle, measured as follows:

a. In a required yard abutting a street, the total effective height above the finished grade measured on the side nearest the street;

b. In any other required yard, the total effective height above the finished grade measured on the side nearest the abutting property;

c. On a property line, measured from the finished grade of either side when the abutting property owners are in agreement; and

d. A temporary fence on a construction site may be as high as required to protect the property during the period of construction.

3. Athletic Facilities. Fencing around athletic facilities, including, without limitation, tennis courts, may be fourteen feet in height so long as all portions above six feet are constructed with at least fifty percent nonopaque materials. Fencing around golf courses and driving ranges may be constructed to a height such that ninety-nine percent of all errant objects are contained as demonstrated by the applicant through submittal of appropriate data/studies and approved by the planning commission. This fencing shall comply with the following requirements:

a. All golf course and driving range netting shall be constructed of black netting and be at least ninety percent transparent;

b. The minimum setbacks shall be the same as for structures in the zone. Setbacks may be increased by the planning commission if it is found necessary to provide appropriate buffering from roadways and adjacent properties;

c. Landscape buffering shall be provided to visually soften the fencing from the vantage point of the motorist and pedestrian. Buffering may include plant materials, berming, or a combination thereof;

d. Poles for fencing shall be painted black, bronze or blue/grey to blend with the sky. The planning commission, based upon a color study submitted by the applicant, shall approve the final color scheme for the poles; and

e. Any other conditions deemed necessary by the planning commission pursuant to the general review criteria noted in Section 17-7-9.9 to mitigate the impacts of the fencing on the surrounding area.

4. Conformance with This Section. No person shall construct, alter, or maintain a fence, hedge, wall, column, pier, post, or any similar structure or any combination of such structures except in conformance with all of the requirements of this section.

D. Reserved.

E. Miscellaneous. Security devices shall have materials and colors that complement the building’s architecture and building materials. Accessory structures shall be architecturally compatible with the primary development. Satellite dishes shall not be placed in view from the front yards.

Table 17-7-9.12.1.8. Architectural Standards

Materials

Configurations

Techniques

Walls

Building Walls: Architectural precast concrete, architecturally treated concrete masonry units, brick cladding, natural and cast stone, architectural metals and glazing. No more than 3 materials shall be used for the primary wall surfaces on a building or fence.

Traditional, time- and weather-tested materials.

Buildings shall use a cohesive palette of colors which complement nearby buildings. Without limiting the use of color, large areas of wall shall be subdued in color and not reflective. Intense colors should be used as accent only.

Retaining Walls: Shall be of materials and color complementary to the building’s materials.

Traditional, time- and weather-tested materials.

Retaining walls shall use a cohesive palette of colors which complement nearby buildings. Without limiting the use of color, large areas of wall shall be subdued in color and not reflective.

Roofs

Roofs & Dormers: All the roofs and dormer roofs of a building shall be constructed of the same material.

Slopes of roofs shall be of equal pitch when a gable or hip roof is employed.

Metal roofs must have a subdued color. Painted shingles are prohibited.

Cornices & Trim: Shall be made with a material and color complementary to building.

Elements

Entry Porches: Front steps shall be constructed of durable materials.

Miscellaneous: Security devices shall have materials and colors that complement the building’s material.

Accessory structures shall be compatible with the primary structure.

Satellite dishes over 18'' shall not be placed in front yards. Awnings shall not be backlit.

External lights shall be located and used to avoid light trespass.

Yard Walls & Fences: Shall be of materials and color complementary to the building’s materials.

Max. height on lot is 7'.

Max. height from front of primary structure forward is 4'. Max. height in sight distance triangle is 3'.

Masonry wall shall be at least 8'' thick and capped by a weather protection top course.

Driveways & Parking: Curbs shall be concrete or asphalt.

Storage yards shall be screened and have paved surfaces.

F. Exterior Structure. All exterior walls of all structures shall be constructed in compliance with the following:

1. All buildings shall use one or more of the following durable materials as significant finish: architectural precast concrete, architecturally treated concrete masonry units, brick cladding, natural and cast stone, architectural metals, and glazing. Architectural site-cast concrete may be allowed if designed, articulated, and colored for a finished appearance on all buildings. At least fifty percent of all buildings visible from 7200 South shall be composed of brick, stone, architecturally treated CMU, and/or architectural precast concrete.

2. High standards for exterior materials, exterior building systems, and their application are expected. In particular, the design and application of EIFS or synthetic stucco are expected to be of a high enough quality to allow for crisp detailing and substantial relief. The use of EIFS on ground floor walls shall be limited to the surface area three or more feet above finished grade. The wall area from finished grade to where the use of EIFS begins shall be clad by a hard, durable material such as brick, stone, architectural precast concrete, or architecturally treated concrete masonry units.

3. Buildings shall provide variation in the form of facades that adjoin streets. Variations should result from significant dimensional changes in plane, color or detail as accomplished by such devices as protruding bays, recessed entries, upper level step-backs, arcades, offsets in the general plane of the facade, changes in materials or color, bay windows, vestibules, porches, balconies, exterior shading devices, nonretractable canopies or awnings, projecting cornices, or eaves.

4. Primary public entry(s) shall be architecturally emphasized so that pedestrians can easily find them.

5. Use awnings, canopies, arcades or other architectural features to reduce glare on storefront glass and to shelter the pedestrians standing near the storefront. Cantilever awnings and canopies from the building face so as to keep sidewalks as clear and unobstructed as possible.

6. Drive-through windows shall be located at the side or rear of buildings. While not desirable, a drive aisle may be located between the building and the street so long as its width is minimized, any pedestrian crossings of it are clearly delineated with special paving treatments, no parking spaces occur off of it and a low wall, railing with landscaping, or a continuous hedge at least three feet high exists between stacked cars and the sidewalk.

7. Opaque (solid) storefront security closures (rolling doors, etc.) are not allowed.

8. Weather Protection. Weather protection features such as awnings, canopies, doors inset by at least three feet, or arcades shall be provided at all customer entrances.

9. Facade Features. All large retail building facades visible from public streets shall include architectural treatments that add detail, character, and reduce the appearance of massive blank walls. Techniques such as color and material changes, expression of structure, shifts in plane, offsets and projections, belt courses, reveals, pilasters, windows, doors, arcades, canopies, and other similar elements may achieve this standard.

10. Parapets. Large building roofs shall have parapets and enclosures concealing flat roofs and rooftop equipment from public view. Parapet and enclosure materials shall match the building in quality and detail.

11. Building Orientation. Building facades that face the street but do not have pedestrian entries shall be composed of high quality materials such as brick or stone, and shall provide variety and interest in the facade through the introduction of such elements as pilasters, recessed or protruding bays, changes in materials and/or colors, building lighting elements, display windows with products or product graphics, transparent windows or clerestories, and well-designed signs and graphics. Service areas, mechanical equipment, meters and trash containers shall be completely screened from the street.

12. Entryways. Each large retail building on a site shall have clearly defined, highly visible customer entrances featuring a combination of several elements such as:

a. Canopies, awnings or porticos.

b. Projecting eaves and cornices.

c. Recesses/projections of wall surfaces.

d. Arcades.

e. Raised parapets over the door.

f. Peaked roof forms.

g. Lighting features.

h. Entry plazas.

i. Display windows.

j. Architectural details such as masonry tile work and moldings which are integrated into the building structure and design.

k. Integral planters or wing walls that incorporate landscaping.

l. Signs integrated with the building architecture.

G. Openings. The following standards apply to openings of all structures:

1. Entry Doors. Entry doors must face the front yard or, if located on the building side, must be placed within three feet of the front facade. Entry doors must be covered by a roof and must be a primary element of the front of the structure.

2. Windows. Bay windows shall have from three to five sides.

3. Corner Buildings. Special attention shall be given to corner buildings that are highly visible, that may serve as landmarks, and provide a sense of enclosure at intersections. Special attention can be achieved by architecture, landscape, and public place.

H. Reserved.

I. Screening. Trash collection and recycling areas, service areas, mechanical equipment and off-street loading areas shall be screened on all sides so that no portion of such areas is visible from public streets and alleys and adjacent properties. Required screening may include new and existing plantings, walls, fences, screen panels, doors, topographic changes, buildings, horizontal separation, or any combination thereof.

1. For nonresidential and mixed-use structures, all roof-mounted mechanical and electrical equipment, communication antennas or dishes shall be screened from the view of a pedestrian at the far side of the adjoining right-of-way or one hundred feet from the front property line, whichever is less, or designed and/or located as part of the overall architectural design.

2. For residential structures, rooftop mechanical equipment, vents, flues, fans and other pieces of equipment shall be screened and/or organized to leave sloped roofs as simple and uncluttered as possible, or, where roofs are flat, to be screened from view of a pedestrian at the far side of the adjoining right-of-way or one hundred feet from the front property line, whichever is less. Where such appurtenances are visible, they shall be painted a color that matches the roof color or other architectural features so that their visual impact is minimized.

3. Refuse containers shall be screened from view on all sides. Screen walls and fences shall be one foot higher than the object to be screened. An opaque gate shall be included where required to complete screening.

4. Off-street loading areas and/or service areas shall be located to the side or rear of buildings. Where they are directly visible from streets, and nearby residential buildings, they shall be screened by walls at least eight feet high, or densely and continuously massed landscaping that maintains its screening capabilities in the winter. Raised planters, berms or other land forms may also be used in conjunction with landscaping or walls. A combination of dense, continuous landscaping and walls may allow the use of lower walls, but no lower than four feet high from finished grade. (Ord. 2022-01 § 1 (Att. B); Ord. 2019-06 § 1 (Att. B (part)); Ord. 2016-15 § 1 (Att. A (part)); Ord. 2015-01 § 1 (Att. A (part)); Ord. 8/1/2006O-12 § 1 (part))